Click on the menu above to see a list of blood pressure measurement devices by Manufacturer and below is a list of devices by Category that meet the validation requirements.
| Manual Devices (Table) |
| |
A&D UM-101 |
Single Validation |
| |
Accoson Greenlight 300 |
Single Validation |
| |
Heine Gamma G7 |
Single Validation |
| |
Heine Gamma XXL-LF |
Single Validation |
| |
WatchBP Office |
Single Validation in Manual Mode |
| |
PMS Mandaus |
Two Validations, one questionable |
| |
PyMaH Mercury |
Single Validation |
| |
Welch-Allyn Maxi Stabil 3 |
Single Validation |
| |
|
|
| Automated Devices for Clinical Use (Table) |
| |
BpTRU, BPM-100, BPM-300 |
Three Validations, some questionable |
| |
Datascope Accutorr Plus |
Three Validations, one questionable |
| |
Dinamap ProCare |
Two Validations |
| |
Microlife WatchBP O3 |
Single Validation |
| |
WatchBP Office |
Single Validation in Automatic Mode |
| |
Omron 705IT (See also SBPM) |
Three Validations |
| |
Omron 907 |
Elderly population |
| |
Omron M4-I (See also SBPM) |
Equivalent to 705IT |
| |
Tensoval duo control |
Single Validation |
| |
Welch Allyn 'Vital Signs' |
Two Validations: one pass and one fail |
| |
|
|
| Upper Arm Devices for Self-measurement of Blood Pressure (Table) |
| |
A&D UA-631 (UA-779 Life Source) |
Single Validation |
| |
A&D UA-705 |
Single Validation |
| |
A&D UA-767 |
Single Validation |
| |
A&D UA-774 (UA-767 Plus) |
Two Validations |
| |
A&D UA-787 |
Single Validation |
| |
Artsana CS 410 |
Single Validation |
| |
Artsana CSI 610 |
Single Validation |
| |
Colson MAM BP3AA1-2 |
Single Validation |
| |
Health and Life HL-868BA |
Single Validation |
| |
Health and Life HL-888HA |
Two Validations |
| |
IEM Stabil-O-Graph |
Two Studies |
| |
Microlife BP 3AC1-1 |
Single Validation |
| |
Microlife BP 3AC1-1 PC |
Equivalent to BP 3AC1-1 |
| |
Microlife BP 3AC1-2 |
Equivalent to BP 3AC1-1 |
| |
Microlife BP 3AG1 |
Equivalent to BP 3BT0-A |
| |
Microlife BP 3BT0-1 |
Equivalent to BP 3BT0-A |
| |
Microlife BP 3BTO-A |
General Validation and three pregnancy validations |
| |
Microlife BP 3BT0-A(2) |
Equivalent to BP 3BT0-A |
| |
Microlife BP 3BT0-AP |
Equivalent to BP 3BT0-A |
| |
Microlife BP A100 |
Single validation; also equivalent to BP A100 Plus |
| |
Microlife BP A100 Plus |
Single Validation |
| |
Microlife RM 100 |
Equivalent to BP 3BT0-A |
| |
Microlife WatchBP |
Single Validation |
| |
Microlife WatchBP O3 |
Single Validation |
| |
Omron 705IT (See also Clinical Use) |
Two validations |
| |
Omron HEM-705CP-II (HEM-759-E2) |
Equivalent to 705IT |
| |
Omron IA2 (HEM-7011-C1) |
Equivalent to 705IT (HEM-759-E) |
| |
Omron i-C10 |
Equivalent to M7 and M6 Comfort |
| |
Omron M1 Classic (HEM-442-E) |
Equivalent to M1 Plus |
| |
Omron M1 Compact (HEM-4022-E) |
Equivalent to M1 Plus |
| |
Omron M1 Plus |
Single Validation |
| |
Omron M4-I (See also Clinical Use) |
Equivalent to 705IT |
| |
Omron M5-I |
Two Validations |
| |
Omron M6 |
Four Validations |
| |
Omron M6 Comfort |
Single Validation + Equivalent to M7 |
| |
Omron M7 |
Two Validations |
| |
Omron M10-IT |
Equivalent to M7 and M6 Comfort |
| |
Rossmax ME 701 series |
Single Validation |
| |
Seinex SE-9400 |
Single Validation |
| |
Sensacare SAA-102 |
Single Validation |
| |
Spengler KP7500D |
Single Validation |
| |
Spengler Pro M |
Single Validation |
| |
|
|
| Wrist Devices for Self-measurement of Blood Pressure (Table) |
| |
Braun BP 3550 |
Single Validation |
| |
BP VitalScan Plus 1650 |
Single Validation |
| |
Braun PrecisionSensor BP2550 (UG) |
Single Validation |
| |
Citizen CH-656C |
Single Validation |
| |
Microlife BP W200-1 |
Single Validation |
| |
Omron 637IT |
Three Validations. Fourth ad-hoc validation may be ignored. |
| |
Omron R5-I |
Single Validation |
| |
Omron R7 |
Single Validation |
| |
|
|
| Devices for ABPM (Table) |
| |
A&D TM-2430 |
Single Validation |
| |
Cardiette BP one |
Single Validation |
| |
IEM Mobil O Graph (version 12) |
Single Validation |
| |
Meditech ABPM-04 |
Single Validation |
| |
Meditech ABPM-05 |
Equivalent to ABPM-04 |
| |
Microlife WatchBP O3 |
Single Validation |
| |
Save 33, Model 2 |
Single Validation |
| |
Spacelabs 90207 |
Several Validations. General recommendation. Not recommended or mixed results in certain groups. |
| |
Spacelabs 90217 |
Single Validation |
| |
Suntech Medical AGILIS |
Single Validation |
| |
Suntech Medical OSCAR 2 |
Two Validations |
| |
Tensioday |
Single Validation |